♧ Features
● ISO 7027 a determination under the provision.
● Wall or panel-mounted housing.
● IR / Tunsten 90 ° scattered light measurement method.
● Bubble removal system.
● User-defined alarm configuration.
● Easy operation by front keys.
● High precision resolution system.
♧ Applications
● For measuring quality of drinking Water, purifying plants
and wastewater treatment plant.
● Ultra pura water manufacturing facility.
● Food & drug process controls
● Industrial use of reprocessing facilities.
● Power plant cooling water.
♧ Technical Specifications
1.Transmitter
● Measuring Unit NTU
● Measuring Range 0.0~10.0NTU / 0.0 ~ 100NTU
/ 0.0 ~ 1000NTU
● linearity 0.1% of F.S.
● Accuracy 2% of reading at below 10 NTU
● Resolution 0.0001 NTU
● Repeatability 0.05 NTU
● Response Time 10sec (90% Saturation)
● Operating Termperature -20~80°C
● Relative Humidity 0 to 95%, None-Condensing
● Analog Output 4-20mA
● Communication output RS232C (OPTION)
● Alarm Contact High, Low, Clean 250VAC 0.5A SPST
● Load Resistance 750ohm Max. Load
● Power Voltage AC110 ~ 220V 50/60Hz ±10%, approx. 3Watt
2.Model
1) CUBE-TU 1000
• Display : 3.5 Inch Graphic LCD
• Max Range : 0.0~500 NTU
• Cleaning System : Air Cleaner / Ultra Sonic Cleaner - Option
• Materials : Glass Fibet Nylon
• Enclosure Rating : NEMA 4X
• Dimension : 96 X 96 X 155
• Install : Panel Mount
2) CUBE-TU 2000
• Display : 5.3 Inch Graphic LCD
• Max Range : 0 ~1000 NTU
• Cleaning System : Air Cleaner / Ultra Sonic Cleaner - Option
• Materials : Glass Fibet Nylon
• Enclosure Rating : NEMA 4X / IP 65
• Dimension : 144 X 144 X 185
• Install : Panel or Wall / Stanchion Mount
3.Sensor
● Light Source IR(LED) / Tungsten
● Measuring Range 0/1000 NTU
● Resolution 0.001 on scale 0/10.000
NTU 0.01 on scale 0/100.0 NTU 0.1 on scale 0/500.0 NTU
● Accuracy 5% of reding on 0/500 NTU
● Response Time 10sec (90% Saturation)
● Measuring method Nephelometric (ISO 7027)
● Optical window material Acrilic
● Sensor Material POM
♧ Features
● Process production lines of the Continuous Monitering.
● Wall or panel mounted housing
● Direct access for manual contact control
● Trustworthy oxygen control
● Automatic temperature, salt, pressure compensation.
● Easy operation by front keys
● Automatic cleaning function (with Chemoclean) triggered
by alarm or limit switch.
♧ Applications
● A wide range of application in ;
● Chemical & petrochemical process
● Food & drug process controls
● O2 control in the aeration basin
● Surface water monitoring
● Waste Water treatment
♧ Technical Specifications
1. Transmitter
● Measuring Principle Polarography Membrane Sensor
● Ranges 0.00 ~ 15.00 mg/l, 0.00 ~20.00 mg/l, ppm, % Saturation Note)
Other ranges are available on request.
● Accuracy ±0.1% of Full Scale Span
● Repeatability 0.01mg/l(ppm) of Full Scale
● Response Time 120sec (90% Saturation)
● Operating Termperature -30~80°C
● Temperature Compensated 0~50°C (Auto or Manual Compensated)
● Relative Humidity 0 to 95%, None-Condensing
● Analog Output 4-20 mA
● Communication output RS232C (OPTION)
● Alarm Contact High, Low, Clean 250VAC 0.5A SPST Note)
Air,Water and Chemical Clean Self-priming and apply pressure.
● Load Resistance 750ohm Max. Load
● Power Voltage AC110 ~ 220V 50/60Hz ±10%, approx. 3Watt
♧ Model specifications
1. CUBE-DO 1000
• Display : 3.5 inch Graphic LCD
• Output
: 1 Chanel Isolated 4 ~ 20m ADC / DO Process Value Output
• Materials : Glass Fiber Nylon
• Enclosure Rating : NEMA 4X
• Dimension : 96x96x155
• Install : Panel Mount
2. CUBE-DO 2000
• Display : 5.3 inch Touch Screen Panel
• Output
: 2 Chanel Isolated 4 ~ 20m ADC / DO, Temp' Process Value Output
• Materials : Glass Fiber Nylon
• Enclosure Rating : NEMA 4X / IP 65
• Dimension : 144X144X185
• Install : Panel or Wall / Stanchion Mount
Sensor
● Model CUBE-DOS
● Measuring Range 0 ~ 15.0 / 0 ~20.0 mg/l(ppm)
● Measuring Principle Polarographic Electrode Method
● Operation Pressure 0.00 ~ 2.0kg/cm2
● Accuracy ±0.1% of Full Scale Span
● Response Time 120sec (90% Saturation)
● Temperature Sensor Pt1000 ohm
● Operating Termperature 0~55°C
● Cleaning System Built in Air(Water) Nozzle
● Standard Cable 5M *Option User ordring Spec
(XonicⓇ 100L)
♧ What is Xonic 100?
Xonic 100 measure transit-time of flow and use
DSP(Digital Signal Processing) technology to analyze ultrasonic signals.
This DSP technology can remove any noise from pipe and electronics.
Also, Xonic 100 use Cross Correlation and FFT(Fast Fourier Transform)
technology to make very clean ultrasonic signals.
Measuring pipe is from 15 ~ 6,000mm,
and velocity range is from 0.02 ~ 12 m/sec.
Xonic 100 can measure very slow flow,
so very suitable for block flow (leak) monitoring system.
Also, it has two 4-20mA inputs,
so user can use this inputs to receive pressure
and temperature data without PLC.
♧ Why use Xonic 100?
Clamp-On Technology make installation very simple.
User just attach clamp-on transducers on pipes
or insertion with hottap valve transducers drill to pipe.
Do not need stop water supply for installation and after service.
Xonic100L can work with many kinds of pipe,
such as: Steel, Stainless (SUS), Ductile Iron, Copper,
A/C, PVC, PE, PB, FRP or others if know sound velocity.
Turn-down ratio of Xonic100L is more than 1000 :1.
Xonic 100L is the best flowmeter to check
minimum flow during mid-nights.
The Flow in mid-night is down to 1 m3/ hr for 100 mm pipe
and Xonic 100L can keep the accuracy.
Xonic 100L use Cross Correlation technology.
The technology is able to remove most noises outside the pipe.
Also, Xonic 100L can measure liquids contain heavy air and slurry.
Xonic 100L has large color graphic LCD.
It allows user to read the flow, total, analog
input data (pressure, level, etc) and the ultrasonic signal diagrem.
So user can check how flowmeter works in field
without oscilloscope as diagnostic functions.
Xonic 100L is dual beam or dual path is basic model.
User can use as single channel flowmeter with one pair transducers,
and dual channel or dual path flowmeters with two pair transducers.
Features and specifications
1. PH-20N
Feature 1-1
• Large and clear Custom LCD
• Design of waterproof design structures
• Battery remaining indicator
• Rechargeable batteries and adapters are included
• Installation support that can be used in the laboratory
• Simultaneous display of measurement data and temperature
and current time display
• Built-in portable case and calibration solution
• Automatic calibration of standard buffers
• Measurement of measurement stability
• Acquired ISO9001, GD, CE mark
1-2 Specifications
PH
• Measuring range: -2.00 to 19.99
• Resolution: 0.01 / 0.1
• Accuracy: ± 0.02
Temperature
• Measuring range: -10 to 110 ° C
• Resolution: 0.1 ° C
• Accuracy: ± 0.4 ℃
Millivolts
• Measuring range: 1999.9mV
• Resolution: 0.1 mV
• Accuracy: ± 0.1mV
Product Size
220 (L) X 80 (W) X 40 (H) / 450 g (Agency)
2. PH-25N
Feature 2-1
• Large and clear Custom LCD
• Design of waterproof design structures
• Battery remaining indicator
• Rechargeable batteries and adapters are included
• Installation support that can be used in the laboratory
• Simultaneous display of measurement data and temperature
and current time display
• Built-in portable case and calibration solution
• Automatic calibration of standard buffers
• Measurement of measurement stability
• Acquired ISO9001, GD, CE mark
• Show the ion concentration
2-2 Specifications
PH
• Measuring range: -2,000 to 19,999
• Resolution: 0.001 / 0.1
• Accuracy: ± 0.002
Concentration
• Measuring range: 0,0001 to 19,999 mg
• Resolution: 0.001
• Accuracy: ± 0.25% of Reading
Temperature
• Measuring range: -10 to 110 ° C
• Resolution: 0.1 ° C
• Accuracy: ± 0.4 ℃
Millivolts
• Measuring range: 1999.9mV
• Resolution: 0.1 mV
• Accuracy: ± 0.1mV
(XonicⓇ 100P)
Xonic 100P is fully digitalized,
easy-to-use portable flowmeter with only 2.4Kg weight.
The Xonic 100P connectors are submersible design which
can be used under harsh environmental conditions including rain
and sun light.
Basic model has two pair of transducer connectors for dual paths
or dual channels.
The Xonic 100P uses patent fine-timeTM DSP technology
to measure virtually any type of liquids with less than 30% solids
or bubbles, such as clean water, waste water, crude oil, etc.
• Clamp-On, Transit-Time
• 1 path, or dual path or 2 channel functions
• 20 hours battery operation
• IP67 Connectors,
• IP67 All Weather Case
• Submersible IP68 Transducers
• Touch Key programming + Remocon
• Large Color LCD Display
• Pulse Output
• Analog Output
• RS-232C Communication
• Datalogging Function with Xonic Software
• Weight 2.4Kg
♧ Application
- As Standard Flowmeter :
Xonic 100P can be used to check the performance of field flowmeters.
The Xonic 100P can be used to compare field flowmeters performance.
- As Field Flowmeter :
The Xonic 100P as portable device to spot-check
various flow installation for virtually any liquids of up to 30% solids
or bubbles.
- As Pipe Material :
Many kinds as CS Steel, SUS(SST), Cast Iron,
Ductile Iron, Aluminum, Brass FRP, PVC or Other
and Liner as: Mortar, Tar Epoxy, PE, Rubber or Other.
♧ Types of Liquids
The Xonic 100P has very strong signal,
which can measure various liquids such as clean water,
waste water, milk, manure, lime stone slurry, oil, gasoline, etc.
Normally, transit-time is only for clean water,
but Xonic 100P can measure all types of liquids using our patented
fine-time TM DSP technology.
- Clean Liquids
- Municipal Water, De-Ionized Water
- Acids, Benzene, Milk, Beer
- Crude Oil, Diesel, Alcohol
- Waste Water, Lime Stone Slurries, Manure
♧ Special Features
- Patented AR Mode
- Patented Fine
- TimeTM Measuring Technology
- DSP Functions
- Cross Correlation, FFT
- Oscilloscope Function
- Flow Velocity 0.02~12.0 m/sec
- Touch Key Programming + Remocon
- Large Color LCD Display
- 20 Hours Operation with Batteries
- Submersible Connectors Portable
♧ Measurenment method
• Measure range
: 0~9.99, 10~99.9, 100~1000NTU
• Accuracy
: + 2% (0~499NTU), + 3%(500~1000NTU)
• Resolution
: 0.01NTU (0~9.99NTU)/0.1NTU(10~99.9NTU)/1NTU
(100~1000NTU)
• Reproducibility
: +1%, +0.01NTU
• Light Source
: Tungsten lamp
• Workable Temperature
: 0~50 C
• Display
: 128 x 64Dot
• Outputs
: RS- 232C
• Power (Voltage)
: Free Voltage (100~240V) lithium ion
• Demensions
: 98(W) x 202(D) x 15(H)mm
• Weight
: 500g
• Consumption
: 25Ø Vial: 6EA / 1Box
STD Solution: 0.1 , 10, 100, 500, 1000 Expiration
• Accessories (Option)
: Thermal Printer , Data download cable
• Waterproof (ip66) housing
• Auto power off function datalog up to 100 points
• Low battery alarm baclit custom LCD display
• Rechargeable battery
• Certificated CE mark GD mark , ISO 9001
• Short response time and easy-to-use using
high sensitive polarograpich type electrode internal diagnosis
for normal operation check B1-directional RS232C allows remote
operation via Pc Simultaneously displays DO (or 02/air/p02) temp
and time automatic temp and barometric pressure compensation.
♧ Specification
DO
• Range : 0.00 ~ 19.99mg / ℓ
• Resolution : 0.1 / 0.01
• Relative Accuracy : ± 0.5%
O2
• Range : 0.0 ~ 60.0%
• Resolution : 0.1%
• Relative Accuracy : ± 1 digit
Air Saturation (%)
• Range : 0.0 ~ 199.9%
• Resolution : 0.1%
• Relative Accuracy : ± 1 digit
Temperature
• Range : -10 ~60℃
• Resolution : 0.1℃
• Relative Accuracy : ± 0.4℃
Dimensions / Weight
• 220(L) X 80(W) X 40(H) / 450g(Body)
♧ Feature
• 4,7,10 PH automatic recognition a buffer
in automated and manual calibration
• wall or panel - mounted housing
• Automatic and manual temperature compensation
• Easy operation by front keys
• Output current, temperature, measured values and a token value emf
• User - defined alarm configuration
• Automatic cleaning function (with chemoclean) trigggered
by alarm or limit switch
♧ Aplication
• For drinking water and waste water treatment processes
• For measuring plate production lines of production
and processing equipment of water
• Food & drug process controls
• For Measuring quality purifying plants, sewage
and waste water treatment plant
• For measuring quality of aqua culture - and fishery
• For power plant control and swimming pool water
♧ Technical Specifications for Per Model
1.Transmitter
● Measuring Principle Glass electrode
● Resolution 0.001 pH
● Measuring Range 0 ~ 14.0 pH / -2000 ~ +2000mV
● Accuracy ±0.1% of Full Scale Span
● Repeatability 0.02pH / 1mV of Full Scale
● Response Time 15sec (90% Saturation)
● Operating Termperature -30~80°C
● Temperature Compensated 0~50°C (Auto or Manual Compensated)
● Relative Humidity 0 to 95%, None-Condensing
● Analog output 4-20 mA
● Communication output RS232C (OPTION)
● Alarm Contact High, Low, Clean 250VAC 0.5A SPST
● Load Resistance 750ohm Max. Load
● Power Voltage AC110 ~ 220V 50/60Hz ±10%, approx. 3Watt
2.Model
1.CUBE-PH1000
• Display : 3.5 Inch Graphic LCD
• Output : 2 Chanel Isolated 4~20m ADC
• Materials : Glass Fiber Nylon
• Enclosure Rating : NEMA 4X
• Dimension : 96X96X155
• Install : Panel Mount
2.CUBE-PH2000
• Display : 5.3 Inch Graphic LCD
• Output : 2 Chanel Isolated 4~20m ADC
• Materials : Glass Fiber Nylon
• Enclosure Rating : NEMA 4X / IP 65
• Dimension : 144X144X185
• Install : Panel or Wall / Stanchion Mount
(XonicⓇ 5L)
System Description Xonic5L is stainless steel,
no moving parts, battery operating,
fully digitalized Water Meter for municipal water applications.
Also, Xonic5L can measure clean water, dirty water, chemicals,
oil, alcohol, etc, so it can replace conventional flowmeters.
No Moving Parts
-No Turbine or Impeller
-No Gear Box
-No Magnetic Parts
Stainless Steel Body
-No Corrosiveness
-No Rust
Fully Digitalized Water Meter
-Ultrasonic Transit
-Time Method
-Bi-Direction Flow
-Empty Alarm
-9.5 Digit Total
-Total & Flow Indication
-Battery Operating (8 Years)
-Pulse Output (1m3/pulse)
-Same Size with Turbine
♧ Application
• Water Meter
• Flow Monitoring Flowmeter
• Flowmeters for
• Chemical
• Steel
• Semiconductor
• Ship Manufacturing
• Oil Refinery
• Irrigation
(XonicⓇ 100MC)
♧ Application
Xonic 100MC measure flow velocity directly
with patented 4 path transducers.
Transducers are located at the end of each side to prevent
any obstructions, and level is located on the top of the open channel,
and accuracy is within 1% of actual flow.
Cross Flow Installation In case of winding open channel,
Xonic 100LM can use Cross Flow Installation to keep better accuracy.
Path 1 & 3, Path 2 & 4 can be installed
as cross path to keep better accuracy.
♧ Specification
• Principle
: Anti-Round Mode, TransitTime With Cross Correlation
• Measuring Path
: 2 or 4 path
• Measuring Width
: 30 meters
• Accuracy
: 2%
• Sensitivity
: 0.01 m/s
• Data Output
: 4-20mADC, Relay RS-232C / RS-485 ModBus
• Data Input
: 4-20mADC
• Datalogger
: 32Mbytes
• Display
: Large Color LCD (128x64)
• Temperature
: Range Electronics : -20 to +60℃
: Transducer : -40 to +120℃
• Power
: 110~220VAC, Free voltage
• Enclosure Electronics
: NEMA 4 (IP65) Transducer: Submersible (IP68)
(XonicⓇ 100LO)
♧ System Description
It is a new sewage flowmeter that
completely overcomes undetectable lowlevel flow rate
and error, which is a chronic problem of
conventional doppler sewer pipe,
and first developed in the world.
Xonic 100LO measure flow velocity directly
with patented 4 path transit-time ultrasonic transducers.
♧ Application
Xonic 100LO is specially designed for sewage pipe only.
It use 4 path transducers to measure flow rate
and use level meter to receive level data.
Also it can measure partly filled pipes.
♧ Flow unit specialized for sewage
Sewage flow rate is usually low,
thus it is difficult to measure it with conventional doppler.
However Xonic 100LO with specially designed flow unit
can measure normal flow as well as very low flow at midnight.
Also it alerts when sand have precipitated
and indicates necessity of maintenance or cleaning.
(XonicⓇ 10LE)
Xonic10LE is
insertion ultrasonic flowmeters
with 1 path, 2 path, 3 paths spool type.
It has no moving parts and fully digitalized
with precise temperature sensors.
Xonic10LE can measure clean water,
dirty water, chemicals, oil, alcohol, etc,
so it can replace conventional flowmeters
♧ Specifications Measuring
• Method Ultrasonic Transit-Time
: 1~3 Pair Insertion Transducers
• Accuracy
: 0.5% RD
• Measuring Range
: 0.05~10 m/s (Flow velocity)
: -40 ~ +150 ℃ (Temperature)
• Sensitivity
: 0.001 m/s
• Temperature Sensor
: PT500
• Output
: RS-232C/485, 4-20mA, Relay
• Display
: Flow & Total
: BTU Flow & Total
: Graphic Mode (diagnostic) - Signal shape, Strength, etc
• Operating Temperature
: -20 ~ +60℃ for Electronics
: -40 ~ +120℃ for Transducers
: -100 ~ +150℃ for Temperature
• Datalogger
: 32Mbytes
• Protection IP68 for Spool IP65 for Electronics Spool Material
: Stainless Steel 304
(WISOP)
♧ System Description
Solar Power Flow Monitoring System
only use solar energy for opereation.
The system has 80W solar panel, and 5 rechargeable batteries,
and clamp-on ultrasonic flowmeter.
Total power consumption of the system is only 5W per hour,
so the system can operate 30 days without sun.
• Only Solar Power Required
• Beautiful Design
• Wireless CDMA Modem Communication
• No Cutting pipe
• No AC Power Required
• No Cooling Fan (unique design for air cooling)
• Patented Design
• Patented AR Mode, Clampon Ultrasonic Flowmeter
• Operate 30 days without sun
• System Consisted of 1 Ultrasonic Flowmeter
5 Rechargeable Batteries 1 CDMA Modem 1 Charge Controller
Application Solar Power Flow Monitoring System
can be used for municipal water monitoring system.
The system is very beautiful, so it make street beautiful
and shop owners do not complain about this solar power panel.
Old cabinet type flowmeter panel is big and ugly also.
• Block Monitoring System for Municipal Water Supply Pipes
• Irrigation Flow Monitoring System
• Waste Water Monitoring System
• Useful For Rural & Desert Area
♧ Specifications
• Power : Solar 80W Panel, 15V Power Consumption
• Communication : Wireless CDMA For Flow, Total, Pressure, etc
• Flowmeter : Clamp-on, Ultrasonic Transit-Time
• Panel Size : height 3.0M, 300Ø Stainless steel
• Date Inputs : Two (Pressure or Level)
(XonicⓇ 10L)
What is Xonic 10?
Xonic 10L Very compact
and cheap but all performence is
same with Xonic 100L model as measure transit-time of flow
and use DSP (digital signal processing) technology
to analyze ultrasonic signals.
This DSP technology can remove any noise from pipe
and electronics. Also, Xonic 10L use Cross Correlation
and FFT (Fast Fourier Transform) technology
to make very clean ultrasonic signals.
with Auto Installation function.
Measuring pipe is from 15 ~ 6,000 mm for Clamp-On
and 80 ~ 6,000 for Instertion applications.
It’s velocity range is 0.02 ~ 12 m/sec.
Xonic 10L can measure very slow flow,
so very suitable for block flow (leak) monitoring system.
Also, it has two 4-20mA inputs, so user can use the input
to receive pressure ,level and temperature data without PLC.
Why use Xonic 10?
Clamp-On Technology make installation very simple.
User just attach clamp-on transducers on pipes or insertion
with hottap valve transducers drill to pipe.
Do not need stop water supply for installation and after service.
Xonic10L can work with many kinds of pipe,
such as: Steel, Stainless (SUS), Ductile Iron, Copper,
A/C, PVC, PE, PB, FRP or others if know sound velocity.
Turn-down ratio of Xonic10L is more than 1000 : 1.
Xonic 10L is the best flowmeter to check
minimum flow during mid-night.
The Flow in mid-night is down to 1 m3/ hr for 100mm pipe
and Xonic 10L can keep the accuracy.
Xonic 10L use Cross Correlation technology.
The technology is able to remove most noises outside the pipe.
Also, Xonic 10L can measure liquids contain heavy air and slurry.
Xonic 10L has large color graphic LCD.
It allows user to read the flow, total,
analog input data (pressure, level, etc) and the ultrasonic signal diagrem.
So user can check how flowmeter works in field
without oscilloscope as diagnostic functions.
Xonic 10L is dual beam or dual path is basic model.
User can use as single channel flowmeter with one pair transducers,
and dual channel or dual path flowmeters with two pair transducers.
(XonicⓇ 10G)
As Xonic-10G Ultrasonic Flowmeter
uses Ultrasonic Transit-Time Technology,
it shows superior performance than
the existing pressure gas flow meter.
Depends on pipe diameter size,
it uses one path or three path ultrasonic sensor(s),
and the temperature sensor is
embedded to give compensation volume.
Xonic-10G is developed as the first ultrasonic type gas flow meters
in Korea and to substitute expensive foreign products
by keeping the ultrasonic flow meters performance
with reasonable price. It is 100% made by Korea.
♧ Field of Application
• Natural Gas Flowmeter
• AIR Supply Lines
• Combustion Gas
• Tunnel Air Flow Control
(XonicⓇ 10LF)
• Same Size with Electro-Magnetic
• No Corrosiveness
• Ultrasonic Transit-time Method
• Bio-Direction Flow